Bass Absorber Panel in Ethiopia
Low Frequency Sound Absorber
BassBloc by MMT Acoustix. The primary bass absorber panel in Ethiopia for professional soundproofing systems. The low frequency sound absorber in Ethiopia engineered from open and closed cell acoustic polyurethane foam compressed and bonded with resin binder at 100 to 125 kg/m3 density. This rockwool alternative acoustic insulation absorbs bass, vibration, and low-frequency energy that mass loaded vinyl blocks but cannot dissipate. Used as a bass trap for home theater, studio, hotel, and industrial acoustic systems in Ethiopia. Available in thicknesses from 25mm to 800mm. Ships to Ethiopia in 14 to 18 days.


Low Frequency Absorption
+ Vibration Control
BassBloc is a polyurethane-based sound absorber that isolates low frequency sound transmission from walls, ceilings, and floors in Ethiopia. Manufactured in high density at our Palwal, Haryana factory to control impact-based sounds, amplified noise, and unwanted sound waves across different frequencies.
BassBloc is composed of super high density closed and open cell polyurethane foam compressed and bonded with resin binder, making it the only material that simultaneously traps and absorbs sound during its conversion from kinetic to heat energy. This open and closed cell combination makes BassBloc absorb bass frequencies up to 10 times more effectively than mineral wool.
- Maximum sound absorption across all frequencies - NRC 1.0
- Controls impact-based sounds and structural vibration
- Absorbs low frequency bass better than mineral wool or glass wool
- Compressibility less than 1mm - no settling or thinning over time
- Non-carcinogenic, odourless, fungi-resistant, no asbestos
- Shelf life greater than a decade - recyclable during renovations

The Only Rockwool Alternative Acoustic Panel That Absorbs Bass
Rockwool and glass wool are rigid mineral fibres. They absorb mid and high frequencies well but reflect low-frequency bass energy because their stiffness does not allow the molecular movement that bass absorption requires. BassBloc's open-cell polyurethane structure flexes at low frequencies, converting bass energy into heat. This makes it the preferred rockwool alternative acoustic insulation for Ethiopia's bass-critical applications - studios, home theatres, and nightclubs.
Open-cell polyurethane structure absorbs bass frequencies below 250Hz where mineral wool is rigid and reflective. NRC 1.0 Class A across the full range.
No glass fibres, no skin irritation, no respiratory dust. Safe to handle without PPE - preferred by Ethiopia installers over mineral wool.
The standard bass trap for home theater and professional studio builds in Ethiopia. Eliminates low-frequency room modes that make cinema rooms boom and studios sound coloured.
Less than 1mm compressibility means no settling. Specified as the decoupling layer between SoundBlanket MLV and finish panels in Ethiopia partition systems.
No off-gassing on installation or in service. Safe for occupied Ethiopia residential and commercial interiors over a 30-year lifespan.
Measured dB Reduction Ethiopia Wall and Ceiling Systems
All performance data tested at ARAI, Pune per ASTM C-423 and ASTM E90. The following configurations are the standard systems specified for Ethiopia residential, commercial, and studio projects.
| Wall System Configuration | dB Reduction |
|---|---|
| 8mm Plywood + MLV 5mm + BassBloc 75mm | 30 dB |
| 4 inch Brick Wall + MLV 5mm + BassBloc 75mm | 50 dB |
| 6 inch Brick Wall + MLV 5mm + BassBloc 75mm | 55 dB |
| 8 inch Brick Wall + MLV 5mm + BassBloc 75mm | 60 dB |
| 8 inch Brick Wall + MLV 8mm + BassBloc 100mm | 70 dB |
System: Wall + SoundBlanket MLV + BassBloc infill. Results verified by ARAI.
| Ceiling System Configuration | dB Reduction |
|---|---|
| BassBloc 25mm + Gypsum False Ceiling | 35 dB |
| BassBloc 50mm + Gypsum False Ceiling | 40 dB |
| BassBloc 75mm + Gypsum False Ceiling | 44 dB |
| BassBloc 100mm + Gypsum False Ceiling | 49 dB |
| MLV 5mm + BassBloc 75mm + Gypsum False Ceiling | 55 dB |
| MLV 8mm + BassBloc 100mm + Gypsum False Ceiling | 63 dB |
System: 8 inch Concrete Ceiling + BassBloc + Gypsum False Ceiling. Results verified by ARAI.
All values dB(A) reduction. STC per ASTM E413. Full test reports available for Ethiopia project specification submission. Values assume installation in a double-leaf partition with staggered stud framing.
Two Proven Systems Wall and Ceiling
BassBloc installs inside wall and ceiling assemblies as the low frequency sound absorber infill layer between SoundBlanket MLV and finish panels. The following are the standard Ethiopia specifications.
Where BassBloc is Specified in Ethiopia
From Bole recording studios to Bole luxury residences, BassBloc bass absorber panels in Ethiopia are the cavity infill layer in every professional low frequency sound absorber in Ethiopia system.
Standard low frequency sound absorber infill in Ethiopia studio wall and ceiling cavities. Eliminates bass build-up and room modes below 250Hz that foam panels cannot address.
The most effective bass trap for home theater builds in Ethiopia. BassBloc in wall and ceiling cavities eliminates the low-frequency modes that make cinema rooms sound boomy.
Guestroom and floor isolation using BassBloc as a rockwool alternative acoustic insulation in partitions of Ethiopia's five-star hotels and premium apartments.
BassBloc above suspended ceilings and inside partitions for Ethiopia offices in Bole and Kazanchis. Controls HVAC rumble and improves STC of glass partitions. Meets WELL Building Standard v2.
Large-scale ceiling and wall infill for Ethiopia multiplexes, auditoriums, and performance venues. Achieves 50 to 60 dB wall ratings and controlled reverberation.
Floor and wall infill for Ethiopia gyms, nightclubs, and machinery enclosures. Controls impact sound, equipment vibration, and amplified bass through building structure.
3-Step Cavity Installation for Ethiopia Projects
BassBloc installs as a friction-fit infill in stud-framed wall and ceiling cavities. No adhesive required for cavity applications. Full guide included with every Ethiopia order.
Install the GI stud framework off the SoundBlanket MLV surface at the correct cavity depth for your chosen BassBloc thickness (20mm, 25mm, 30mm, or 40mm). Ensure studs are not in hard contact with the structural wall to prevent vibration flanking.
Cut BassBloc panels to size with a sharp utility knife. Press friction-fit into the stud cavities. BassBloc's compressibility (30% at 3.5 kPa) ensures tight cavity contact without gaps. Butt-join sheets at stud centres with no overlap required.
Fix the finish layer (Gypsum, HDHMR, or Echsorbix Felt Panel) over the BassBloc-filled stud frame. For ceiling systems, staple BassBloc to the GI frame before fixing gypsum to prevent gravity pull-through. All Ethiopia orders include a full installation drawing set.
Why Ethiopia Specifies BassBloc
New Delhi facility. No resellers. Direct pricing for Ethiopia.
NRC 1.0 and full dB data tested at ARAI Pune. Reports accepted for Ethiopia submissions.
7 days production plus 7-10 days transit. Total 14-18 business days to Ethiopia.
CEPA in force since 2010. May reduce applicable import duty for Ethiopia orders.
Share drawings, get BOQ within 24 hours. Physical samples dispatched free.
BassBloc and SoundBlanket MLV ship together from one manufacturer, one invoice.
BassBloc in Ethiopia Common Questions